Preferred Client

Fan/Filter Units (FFUs) and Power Distribution Modules

Refer to the Application Guidelines for recommendations on quantities to meet specified requirements for cleanliness and lighting.

Power Distribution Modules
Power Distribution Module

View Power Configuration
Dramatically simplifies connection of ceiling lights and fan/filter modules (FFUs) and allows operation from a single Control Panel (no. 6600-23, order separately). Each accommodates up to 5 lights and 5 FFUs and includes a step-down transformer for low-voltage control and operation status indicator circuits. Includes relays and circuit breakers for overload protection of all connected devices, AC contactors, and NEC-compliant quick-connect fittings for lights and FFUs. Price includes installation on specified Terra cleanroom. Each module must be wired to a dedicated 20A fused 120 or 240VAC circuit.

  Cat. # $/Each
120V 6600-29 Login
240V 6600-29-220 Login

Power Distribution Module, Single Point of Connection

View Power Configuration
Similar to the unit above, but includes NEC electrical enclosure mounted to the side of the cleanroom that provides easy access to serviceable components, including circuit breakers. Electrical panel allows multiple Power Distribution Modules and all other cleanroom electrical equipment to be hard-wired to a single dedicated power source, reducing reliance on an electrical contractor to complete cleanroom installation.

  Cat. # $/Each
120V 6600-28 Login
240V 6600-28-220 Login

Fan / Filter Unit
Fan/Filter Unit

Wafer/CE UL LOGO

UL listed and CE marked models available; inquire when ordering
 

HEPA or ULPA Fan/Filter Unit (FFU)

  • Quiet, low-vibration design: only 49 dBA, measured 30" from filter face @ 90 FPM
  • Low-profile design allows installation of a 7'-high cleanroom beneath a standard 9' ceiling
  • Provides an average air flow velocity of 90 feet per minute (.45 m/sec) and air flow of 600+ CFM under filter load, per cleanroom standards (2' x 4' model)
  • Three-speed switch (on 2' x 4' models) provides low, medium and high settings
  • Meets IEST Recommended Practices

These reliable, self-powered Filter/Fan Units provide a reliable flow of microfiltered air to meet cleanliness standards down to Class 1 (ISO 3). See Application Guidelines for filter application guidelines.

Advanced baffling technology ensures uniform airflow across the filter face and attenuates sound for quiet operation: approximately 49 dBA. Select HEPA (High-Efficiency Particulate Air) filters, rated 99.99% efficient @ removal of particles 0.3µm and larger, or ULPA (Ultra-Low Penetration Air) filter, rated 99.9995% efficient @ removal of particles 0.128µm and larger.

The durable powder-coated steel lid and body features a slide-in prefilter, for easy replacement and maintenance. The 2 x 4 models use a 3-speed, centrifugal-type fan/motor with permanently lubricated bearings. Other sizes use a speed control for a full range of settings.

All prices are for turnkey systems and include wiring and panel-mount on/off control. Gel-sealed, DOP-tested, and CE marked units available; call Terra for pricing.

Specifications
Dimensions: 23-5/8: x 47-5/8” x 12-1/2” high
Housing: Plenum is cold rolled steel finished with white powder baked enamel. Compatible with 1-1/2” grid on 24” x 48” centers or 2” grid on 24.5” x 48.5” centers.
HEPA Filter: HEPA filter is 99.99% efficient on removal of particles 0.3 microns and larger by DOP test. Filter module must be removed from the ceiling for HEPA filter replacement.
Prefilter: 20” x 20” x 1” – UL classified for Class 1; rated 80% efficient on linty dusts
Blower: Forward curved centrifugal type factory balanced. Entire motor/blower assembly is removable from top of housing for service.
Motor: 1/4 HP Direct drive, energy efficient. Permanent split capacitor type. Thermally protected with automatic overload reset.
Electrical: 3-speed motor switch (lo-med-high) and separate on/off switch (2x4 models). Motor leads are wired to a Mencom 4- pin connector for field connection.
Face Grille: Face grille perforated anodized aluminum.
Noise Level: 49 dBA
Weight: 76 lbs shipping weight
Support: 1/4” eyebolts are installed in all (4) corners for hangwire support
Power Specifications (for 2x4 HEPA, 120v model)
  High Speed Medium Speed Low Speed
Voltage 119v 98v 84v
Run Amps 4.3 3.5 3.3
Watts 512 343 277
Start Amps 9.1 6.3 4.9
Air Speed
  High Speed Medium Speed Low Speed
2x4 HEPA Unit 93 fpm 87 fpm 80 fpm
Filter Fan Units with HEPA Filter (HS: High Speed; MS: Medium Speed; LS: Low Speed)
Model Dimensions
Inches
(mm)
Weight
lbs.
(Kg)
Average Airflow CFM
(m3/hr)
Power With
HEPA Filter
HS MS LS Cat. # $/Each
2 x 4 23.63 x 47.63 x 12.51
(600 x 1210 x 318)
65
(29)
717 668 646 120VAC, 60Hz 6601-24-H Login
220VAC, 60Hz 6601-24-H-220 Login
2 x 3 23.63 x 35.63 x 12.51
(600 x 905 x 318)
52
(24)

580

530 500 120VAC, 60Hz
6601-23-H Login
220VAC, 60Hz 6601-23-H-220 Login
2 x 2 23.63 x 23.63 x 12.51
(600 x 600 x 318)
39
(17)
390 375 360 120VAC, 60Hz
6601-22-H Login
220VAC, 60Hz 6601-22-H-220 Login
Filter Fan Units with ULPA Filter (HS: High Speed; MS: Medium Speed; LS: Low Speed)
Model Dimensions
Inches
(mm)
Weight
lbs.
(Kg)
Average Airflow CFM
(m3/hr)
Power With
ULPA Filter
HS MS LS Cat. # $/Each
2 x 4 23.63 x 47.63 x 12.51
(600 x 1210 x 318)
65
(29)
660 600 550 120VAC, 60Hz 6601-24-U Login
220VAC, 60Hz 6601-24-U-220 Login
2 x 3 23.63 x 35.63 x 12.51
(600 x 905 x 318)
52
(24)

580

530 500 120VAC, 60Hz
6601-23-U Login
220VAC, 60Hz 6601-23-U-220 Login
2 x 2 23.63 x 23.63 x 12.51
(600 x 600 x 318)
39(17) 390 375 360 120VAC, 60Hz
6601-22-U Login
220VAC, 60Hz 6601-22-U-220 Login

Ionizing bar

Ionizing Bar

Includes ionizing bar, power supply, and installation kit; Ionizing kit and FFU must be ordered together.
IonBar ™ with Installation Kit
For use with
FFU sizes below
110 VAC 220 VAC
Cat. # $/Each Cat. # $/Each
2 x 2 2005-47 Login
2005-47-220 Login
2 x 3 2005-48 Login
2005-48-220 Login
2 x 4 2005-49 Login
2005-49-220 Login

Clean Room Filter / Fan Unit Control

EnergySaver Filter-Fan Unit Control —
Cuts Operating Costs and Heat Generation!

  • Programmable filter/fan unit control lets you adjust blowers individually from a central monitor/display panel
  • Independent blower control (20 – 100% full speed) allows variable flow rates within a single cleanroom
  • “Not-In-Use” setting maintains desired cleanliness at lower fan speeds to save energy, cut heat generation when room is unoccupied
  • Passcode security protection guarantees tamper-resistant FFU operation
EnergySaver FFU Control (installed) Cat. # $/Each
One required per Filter/Fan Unit* 6702-19 Login
* Order Power Supply and Monitor Display Panel separately
Power Supply Cat. # $/Each
AC main to 12V DC, 115V 6702-31 Login
AC main to 12V DC, 220V 6702-31-220 Login
EnergySaver FFU Monitor/Display Panel (installed) Cat. # $/Each
Each operates up to 10 FFUs. Configurations available
for large rooms with many FFUs; call Terra.
6702-20 Login
Solutions by Industry
Builders(AEC) | Pharmacies
Forensic Labs | Animal Labs
QuickQuote Planner
Online Configuration
Online Configuration
QuickQuotes help you specify select systems to your requirements.
 
Need It Right Away?
Blue Prices Indicate QuickShip Items
Blue Prices Indicate QuickShip Items
These ship within a week, usually the very next day. Call for available quantity.
 
Featured Product
Space-Saving Convenience!
Space-Saving Convenience!

Complete line of stainless steel dispensers, racks and bins, now with antimicrobial surface

 
Featured Product
Uncompromising Cleanliness
Uncompromising Cleanliness

BioSafe™ Passthroughs ideal for aseptic environments

 
Need It Right Away?
Ask About Terra's QuickShip Program
Ask About Terra's QuickShip Program
Available for hundreds of products!